Current and Voltage Process Calibrator Accuracy 0.05%
Precision current voltage frequency calibrator is a hand-held process controlling signal calibration meter with high precision, high resolution and high reliability. It integrates output and measurement of V, mV, mA and Hz signals. This Volt mA calibrator has large liquid crystal display with clear reading, and it also has adjustable back light source and automatic shutdown function. The calibrator can be powered by DC power supply or AAA dry battery, which is more convenient to use. It is an ideal replacement of other brands Volt/mA Calibrator, Loop Calibrator, etc.
Main Features & Benefits
• High accuracy: 0.05%
• Handheld shell, support dry battery power supply, LCD with adjustable backlight.
• Perfect performance on waterproof protection: IP67 grade.
• Source of voltage, current and frequency, 4-20 transmitter output simulation.
• Have manual stepping, automatic stepping and 0-100% output of phase step and ramp function.
• Manual stepping, automatic stepping and ramping.
• Measure voltage, current, loop current and frequency signal.
• In case of connecting 220V, it has automatic over voltage protection function.
V mA Source and Measurement Parameters
Function | Source output | Measurement |
DC V | 0-10V | 0-30V |
DC mV | 0-100mV | 0-100mV |
DC mA | 0-24mA | 0-24mA |
Frequency | 0.00Hz~20.000kHz | 1.000Hz~99.999kHz |
Others | 24V power supply, Step, Ramp. |
General Parameters
• Using environment temperature: -18℃~55℃
• Storage environment temperature: (-20 – 60)°C
• Relative humidity :0~ 90RH No condensation
• Weight: 0.35Kg
• Size: 185mm×93mm×47mmm
• Power supply: 6 R03-model rechargeable batteries or power adapter
Source Output Parameters
Range | Max. output span | Resolution | Accuracy (% of reading + Counts) |
100mV | -15mV~99.999mV | 0.001mV | 0.05+20 |
100mV | 100mV~125mV | 0.01mV | 0.05+2 |
10V | 0~11V | 0.001V | 0.05+2 |
20mA | 0~24mA | 0.001mA | 0.05+2 |
200Hz | 0~200Hz | 0.01Hz | 0.02+1 |
2000Hz | 0~2000Hz | 0.1Hz | 0.02+1 |
20KHz | 0~20kHz | 1Hz | 0.02+1; |
• Frequency Output amplitude: ≥4.5Vp-p; Wave form: square wave.
• All the parameters testing conditions: -10℃~18℃, +28℃~55℃, temperature coefficient, ±0.005%FS/℃.
• Voltage output maximum load: 1mA or 1kΩ (It should be based on the lower load.)
• Current output maximum load voltage: 20V, equivalent to voltage of 20mA on 1000Ω load resistance.
Frequency Measurement
Range | Max. measurement range | Resolution | Accuracy (% of reading + Counts) |
30V | 0V~31V | 0.001V | 0.05+2 |
100mV | -15mV~125mV | 0.01mV | 0.05+2 |
20mA | 0~24mA | 0.001mA | 0.05+2 |
100Hz | 1~99.999Hz | 0.001Hz | 0.02+1 |
1000Hz | 100~999.99Hz | 0.01Hz | 0.02+1 |
10kHz | 1k~9.9999kHz | 0.1Hz | 0.02+1 |
100kHz | 10k~99.999kHz | 1Hz | 0.02+1 |
• Frequency Measurement sensitivity: 10Hz~10kHz, Vp-p≥1V; the rest: Vp-p≥2V.
• Wave form: 5 counting points should be added to errors of other wave forms. Industrial frequency can be measured directly.
• DC Voltage measurement: -10℃-18℃, +28℃-55℃, temperature coefficient, ±0.005%FS/℃. Input resistance: >1MΩ.
• DC Current measurement: -10℃-18℃, +28℃-55℃, temperature coefficient, ±0.005%FS/℃. Input resistance:<100Ω.
- Operating temperature: -10℃~55℃;
- Storage temperature: -20℃~60℃;
- Relative temperature: 0~90%RH, non-condensing;
- Weight: 650g;
- Dimensions: 185×93×47mm;
- Power supply: 6 7# batteries or AC adapter (standard);
- Communication method: RS232 (optional);
- Standard accessories: 1 pair of test leads, 1 charger.
General | |
Batteries Inside | Rechargeable battery |
English Instruction | YES |
HS Code | 9030339000 |
Original | Shajing, Shenzhen |
Current Voltage Frequency Calibrator 0.05%
- Brand: ROKTOOLS
- Product Code: PRCA-52002
- Availability: In Stock
-