Power Quality Analyzer Class A Energy Analyzer Harmonic Tester
Ask sales reps for details.
Part No: PQAN7620
Features:
More accurate up to 0.1% on Vrms(voltage), Frequency: 0.01Hz
Meet standard: IEC61000-4-30 Class S
Phase: -180~180
Lart 5.6 inch TFT LCD 640*480 resolution
With USB and lan interface
Safety standard: IEC61010-1 ,Safety Degree: 600V CAT IV 1000V CAT III
Specification:
Selection Table | |
Model | PQAN7610 |
Standard compliance | IEC61000-4-30 Class A |
Volt Amp Hz | ● |
Dips and swell | ● |
Harmonics | ● 100th Max. |
Power and energy | ● |
Unbalance | ● |
Monitor | ● |
Inrush | ● |
Flicker | ● |
Transients | ● |
400Hz | ● |
Wave Recording | ● |
Sample rate | 163.84kS/s (50/60Hz) |
TF Card | 32GB |
Battery | Lithium ion, 7.4V 5200mAh |
GPS/Beidou time synchronization | ● (option) |
WIFI | ● |
Input Characteristics | |
Number of inputs | 4 (3 phase + neutral) DC coupling |
Voltage Inputs | |
Max. input voltage | 1000Vrms |
Max. peak measurement voltage | 6kV |
Input Impedance | 4MΩ |
Current Input | |
Type | Clamp or current transformer with mV output |
Input Range | depends on supplied current clamp |
Input Impedance | 50kΩ 100kΩ (SA2200) |
Sampling System | |
Resolution | 8 channels 16 bits AD |
Sampling Rate | 163.84kS/s (50/60Hz), 8 channels sample
synchronously (SA2200) |
Measurement | |||
Measurement Range | Resolution | Accuracy | |
Voltage/Current/Frequency | |||
Vrms(AC+DC) | 1 ~ 1000Vrms | 0.01Vrms | ±0.1% of nominal
voltage |
Vpk | 1 ~ 1400Vpk | 0.01Vpk | ±0.5% of nominal
voltage |
V(Crest Factor) | 1.0 ~ >2.8 | 0.01 | ±5% |
Arms(AC) 10mV/A 1mV/A 65mV/1000A (AC) |
|||
0~150A | 0.01A | ±0.1%±0.1A | |
1~2000A | 0.01A | ±0.1%±0.1A | |
10~6000A | 0.01A | ±1%±2A | |
A(Crest Factor) | 1 ~ 10 | 0.01 | ±5% |
Frequency | 42.5~57.5(50Hz nominal) | 0.01Hz | ±0.01Hz |
51~69(60Hz nominal) | 0.01Hz | ±0.01Hz | |
320~480(400Hz nominal) | 0.01Hz | ±0.01Hz | |
Dips & Swells | |||
Vrms1/2 | 0 ~ 200% of nominal voltage | 0.01Vrms | ±0.2% |
Arms1/2 | depends on current clamps | 0.01A | ±1% |
Harmonic (IEC61000-4-7) | |||
Harmonic Number | 1 ~ 100(50/60Hz) (IEC61000-4-7) 1~12(400Hz) | ||
Harmonic Voltage %f | 0.0 ~ 100.0% | 0.01% | ±0.1% ± nx0.1% |
Harmonic Current %f | 0.0 ~ 100.0% | 0.01% | ±0.1% ± nx0.1% |
THD | 0.0 ~ 100.0% | 0.01% | ±2.5% |
Phase | -180° ~180 0° | 0.1° | ± nx0.1° |
Power and Energy | |||
P, S, Q1 | Max. 6000MW | 0.1kW | ±1%±10 digits |
PF & cosФ | 0 ~ 1 | 0.01 | ±0.1% |
kWh, kVAh, kvarh | depends on nominal voltage and current clamps | ±1%±10 digits | |
Flicker (IEC61000-4-15) | |||
Pst(10min)/Plt (2 hrs) | 0.00 ~ 20.00 | 0.01 | ±5% |
Unbalance | |||
Voltage | 0.0 ~ 20.0% | 0.1% | ±0.1% |
Current | 0.0 ~ 20.0% | 0.1% | ±1% |
Voltage Phase | -360° ~ 0° | 0.1° | ±0.1° |
Current Phase | -360° ~ 0° | 0.1° | ±0.5° |
Voltage Transient | |||
Vpk | ±6000Vpk | 1V | ±15% |
Vrms | 10 ~ 1000Vrms | 1V | ±2.5% |
Min. Test Time | 6.5us | ||
Inrush Current | |||
Arms | depends on current clamps | 0.01 | ±1% ± 5digits |
Inrush Duration | 1 ~ 32min selectable | 10ms | ±20ms |
Logger | |||
Recording | user-defined parameters for 4 phases at the same time | ||
Memory | Data stored in TF card, 32GB | ||
Duration Time | 2 hrs to 1 year, depends on the recording items and time interval | ||
Interval | 1s to 60 minutes |
CT clamps: (Option)
A: Range: 5A, Output Voltage Ratio: 10mV/A Accuracy: 0.2%
Working Frequency: 45Hz~55Hz Clamps Radius: 8mm
Size: 158*43*24mm
B: Range: 50A, Output Voltage Ratio: 10mV/A Accuracy: 0.2%
Working Frequency: 50Hz~400Hz Clamps Radius: 8mm
Size: 171*46*27mm
C: Range: 100A, Output Voltage Ratio: 10mV/A Accuracy: 0.2%
Working Frequency: 50Hz~400Hz Clamps Radius: 13mm
Size: 174*52*27mm
D: Range: 1A~1000A, Output Voltage Ratio: 1mV/A Accuracy: 1%
Working Frequency: 40Hz~100Hz Clamps Radius: 52mm
Size: 111*216*45mm
E: Flex type Primary Current Rating: 3000A , Output Voltage Ratio: 65mV/1000A
Range: 15A~3000A Accuracy: 1%+position Error
Maximum Allowable imput: 100KA Phase Error: Less than 1%
Noise: less than 2mVrms(10Hz~10Khz) Frequency Characteristic: 10Hz~10KHz(-3db)
Weight: 130g Length: 200cm CT perimeter: 50cm Postion Error: 2%
F: Flex type Primary Current Rating: 5000A , Output Voltage Ratio: 50mV/1000A
Range: 20A~1000A Accuracy: 1%+position Error
Maximum Allowable imput: 100KA Phase Error: Less than 1%
Noise: less than 2mVrms(10Hz~10Khz) Frequency Characteristic: 10Hz~10KHz(-3db)
Weight: 130g Length: 200cm CT perimeter: 50cm Postion Error: 2%
General | |
Batteries Inside | Lithium ion, 7.4V 5200mAh |
Characteristic | Dips and swell, Harmonic(IEC61000-4-30), Power and Energy |
Power Quality Analyzer Class A Energy Analyzer Harmonic Tester
- Product Code: PQAN-7620
- Availability: 2-3 Days
-
$3,328.00
Related Products
LRS-100-24 Enclosed Power Supply PSU 1 Output
LRS-100-24 Enclosed Power Supply PSU 1 Output Features Withstand 300 VAC surge input for 5 ..
$16.99
Voltage Frequency Current Switch Digital Wattmeter Electronic Power Meter
Voltage Frequency Current Kwh Power Switch Digital Wattmeter Electronic Power Meter ..
$10.99
S10 Color screen Color Screen Multimeter 9999counts
S10 Color screen Color Screen Multimeter 9999counts Features: 1.The High-definition la..
$25.99
Grounding Resistance Meter Digital Earth Resistance Tester AC voltage Dust Proof
Grounding Resistance Meter Digital Earth Resistance Tester AC voltage Dust Proof Features: Groun..
$85.99
8-120V Coulomb Counter 50A Battery Capacity Detector
120V Coulomb Counter 50A Battery Capacity Type A 0-75A Specification Voltage: 8~120V Current..
$39.99
V8 Finder Pro Satelliet Finder DISEQC
V8 Finder Pro Satelliet Finder DISEQC Auto Calculate Angle of AZ EL 4.3 Inch High Defini..
$93.99
Earth Ground Resistance Tester Low Resistance Measurement Tools Earth Voltage Meter
Earth Ground Resistance Tester Low Resistance Measurement Tools Earth Voltage Meter..
$218.88
UT116A UT116C SMD Tester Resistance Capacitance Diode Battery Voltage Tester
UT116A UT116C SMD Tester Resistance Capacitance Diode Battery Voltage Tester UT116A C..
$18.66
Tags: Power Quality Analyzer, Energy Analyzer, Harmonic Power Analyzer
Featured
DIN 862 Digital Caliper Extra Large Display Vernier Caliper Slide
DIN 862 Digital Caliper Extra Large Display Vernier Caliper Slide ISO17025 Not Including Th..
$28.99 $35.99
Steel Wire Rope Hoisting Cable Diameter Digital Caliper Sponge Thickness Vernier Caliper
Steel Wire Rope Hoisting Cable Diameter Digital Caliper With Large Measuring Jaw Sponge Th..
$77.99
Universal Bridge Cam Welding Gage
Universal Bridge Cam Welding Gage WGU-8M WG-218 is updated from ROK WG-208, These two ..
$18.99
Dual Range NCV test 35/6 Bit Digital Multimeter
Dual Range NCV test 35/6 Bit Digital Multimeter Features: 1. AC DC measureme..
$48.90
Latest
DC/AC Automobile Leakage Current Clamp Meter
DC/AC Automobile Leakage Current Clamp Meter It is also known as car leakage ..
$118.88
4-channel Current Power Quality Analyzer
4-channel Current Power Quality Analyzer Functions 1.Real time waveform display (3 channels volt..
$1,780.00
Non Magnetic Micrometer 0-100mm Antimagnetic Outside Micrometer
Non Magnetic Micrometer 0-100mm Antimagnetic Outside Micrometer The tips are made of materi..
$310.00
Stainless Steel Wet Film Comb Thciness Gauge 50-10000um
Stainless Steel Wet Film Comb Thciness Gauge Size: Size:Approx.100x42mm/3.94x1.65inch Ran..
$8.88
100mm Long Reach Outside Caliper Gauge With 500mm Deep Throat
100mm Long Reach Outside Caliper Gauge With 500mm Deep Throat Features: -Graduation: metric&nb..
$220.00
0-50mm Outside Caliper Gauge With 500mm Deep Throat
0-50mm Outside Caliper Gauge With 500mm Deep Throat It measure thickness appli..
$199.00
0-50mm Caliper Gauge With Long Arm 300mm Depth
0-50mm Caliper Gauge 300mm Long Jaw Features: -Graduation: metric 0.05mm -Packed..
$137.00
0-50mm Outside Caliper Gauge With 200mm Depth
0-50mm Caliper Gauge 200mm Depth Features: -Graduation: metric 0.05mm -Pin ..
$109.00